Description
The AC-30B is ideal for applications testing larger wires, multi-conductor cables, or whenever more than 15kV is required. The A-30B meets a variety of common industrial specifications including UL 2556, UL 1581, and IEC 62230 (when properly applied and using an application appropriate electrode).
Voltage Test Range : Approximately 1kV to 30kV RMS, depending on electrode type and product under test.
Test Frequency : Mains frequency 50 or 60Hz
Output Power : 6mA Resistive
Fault Indication : White 3-digit 20.32mm high LED display, amber fault indicating LED
Fault Resolution : Variable with electrode length or directly configurable from 2 milliseconds to 2 seconds
Detection Sensitivity : Conforms to IEC 62230
Operating Modes : Continuous HV/remove voltage on fault, momentary process control/latch until reset